PneumaCell™ Test
The design and manufacturing of PneumaCell™ fully comply with the ISO 17357-1:2014, yet go beyond its requirements. Additionally, PneumaCell™ adheres to the guidelines of OCIMF and PIANC to comprehensively imporve fender performance.
FENDER-EDGE
PneumaCell™ Test Report Preface
This report provides a detailed breakdown of PneumaCell™ (Pneumatic Fender) performance test into three parts. These three parts directly determine the safety performance, enabling users to intuitively and logically understand the superiority of PneumaCell™.
PneumaCell™ Compression Performance Test
Verifying the pneumatic fender energy absorption, reaction force and compression performance comply with ISO 17357-1:2014 requirements.
PneumaCell™ Hydrostatic-Pressure Test
The hydrostatic-pressure test shall be performed for 10 min at the hydrostatic pressure shown as “Test pressure at 0 % deflection” in ISO 17357 “Pneumatic 50 Fender Pressure Requirements” or “Pneumatic 80 Fender Pressure Requirements” and there shall be no leakage of water and no defects during the test.
PneumaCell™ Hydrostatic-Pressure Burst Test
After completing the above “Hydrostatic-Pressure Test”, continue to inject water into the test fender to measure the water pressure bursting value of the test fender.